Overview Specs

Overview
This series is a double conversion Power Converter which produces stable pure sine wave voltage and frequency output (O/P). With this Converter, you can protect your equipment from most power issues, including power sags, power surges, brownouts, and line noise. With the common neutral topology, the converter provides internal connection from AC I/P neutral to AC O/P neutral; thus, it does not need to use an isolation transformer to provide 0 volt from AC I/P neutral to O/P neutral. This feature will reduce the interference to loads of communication or video systems.

Features

  • Outstanding Performance & Reliability
  • Common Neutral, Double Conversion Topology (0/P Neutral to 1/P Neutral is O volts normally)
  • Wide Range Input Window and Input Power Factor Correction
  • Low Noise, Smart Cooling Fan Design
  • High Efficiency, New Full-bridge Inverter Design
  • Automatic Restart After Overload Shutdown
  • AC Input Generator Compatible
  • Remote Emergency Power Off
  • Multifunction LCD Screen

SPECIFICATIONS

STEP-UP Voltage and Frequency Converter (UX / Tower Series)
Models UX-1K UX-1.5K UX-2K UX-3K
Output
Capacity 1000VA/900W 1500VA/1350W 2000VA/1800W 3000VA/2700W *
Output Voltage 200V/220V/230V/240V Selectable
Voltage Waveform Sine wave
Crest Factor 3:1
Output Frequency
(sync to mains)
N/A
Output Frequency
(not sync to mains)
50/60Hz (selectable from LCD function button)
50±0.01Hz or 60±0.01Hz
Regulation ±2% of selected output voltage
(adjustable by using the setting software)
Output Current
200 V ~ 240 V
4.2 Amp 6.3 Amp 8.4 Amp 12.5 Amp
Output Peak Current
(<250mS)
13 Amp 20 Amp 27 Amp 37 Amp
Overload protection 100%~129% for 60 seconds, then audible alarm; audible alarm sounds for 60 seconds before shutting down
>130%, alarm will go off for 2 seconds and then shutting down
Harmonic Distortion <3% (at full resistive load)
Efficiency Up to 90%
Input
Voltage Range 100V~285Vac 240 Volts Range: 180V~285V
Requires a dedicated 240-volt power
Frequency Range 45~70Hz
Input current 10 Amp 15 Amp 20 Amp 20 Amp
Wall-Outlet Type Required NEMA 5-15 R 15 Amps
NEMA 5-15 R
(15 Amps)
NEMA 5-20 R 20 Amps
NEMA 5-20 R
(20 Amps)
NEMA 5-20 R 20 Amps
NEMA 5-20 R
(20 Amps)
NEMA 6-20 R 20 Amps
NEMA 6-20 R
(20 Amps)
Power Factor >=0.98
Surge Current <100A, 3mS
Communications & Management
Control panel LCD
Audible alarm Overload alarm: Short-circuit alarm, Thermal alarm
Environmental and Safety
Operating Temp. Up to 1500 meters: 0℃ to 40℃ (32℉ to 104℉)
Transit/storage Temp. -15℃ to 55℃ (5℉ to 131℉)
Relative Humidity 5 - 95% non condensing
Operating Altitude 0 ~ 3000 meters
Audible noise =<45 dBA (at 1 meter from surface of unit)
Safety Markings BSMI CE
Quality control system ISO9001
Physical
Models UX-1K UX-1.5K UX-2K UX-3K
Dimensions
D x H x W
38×20×18cm
15×8×7in
45×20×18cm
18×8×7in
51×20×18cm
20×8×7in
51×20×18cm
20×8×7in
Weight 6.5 kg / 14.0 lbs 7.0 kg / 15.5 lbs 8.0 kg / 17.6 lbs 8.5 kg / 19.0 lbs
Shipping Dimensions
D x H x W; Weight
48.0×33.0×30.0cm; 8.5 kg
19.0×13.0×12.0in; 19.0 lbs
54.0×33.0×30.0cm; 9.0 kg
21.0×13.0×12.0in; 20.0 lbs
61.0×33.0×30.0cm; 10.0 kg
24.0×13.0×12.0in; 22.0 lbs
63.5×33.1×35.6cm; 10.9 kg
25.0×13.0×14.0in; 24.0 lbs
PS.“﹡” Please refer to the input range for the condition of output rated capacity.